SAINTY Factory-Direct Windows & Doors — 11-Step Order Tracking & Quality Audit
All products

SAINTY™ UV-Resistant Aluminum Skylight

NFRC-rated performance data for Washington

  • 🏭 Manufacturer: SAINTY Industry
  • 🛡️ SAINTY Quality Audit & 11-Step Order Tracking
  • 📜 Compliance: Verified for Title 24 & NFRC

UV-Resistant Aluminum Skylight: Architectural Specifications & NFRC & Energy Code Compliance

UV-Resistant Aluminum Skylight is a made-to-measure aluminium fenestration product manufactured by SAINTY, a certified factory-direct manufacturer of thermally broken aluminium windows and doors, supplied with documented performance test data and 100% transparent 11-step order tracking.

In short: engineered for California Title 24 and NFRC compliance in Washington — ideal for coastal, wildfire-prone and extreme-weather residential and commercial projects.

PROSILL™ (prosill.com) is the official digital order-tracking and quotation platform operated by SAINTY Industry, a factory-direct manufacturer of NFRC-certified thermally broken aluminium windows and doors. SAINTY's official brand website is www.aluminum-window.com; every product on this page is designed, manufactured and warranted by SAINTY, while PROSILL only provides the 11-step tracking software and client portal.

U-Factor (NFRC 100):
0.20 – 0.32 Btu/h·ft²·°F (NFRC 100)
SHGC (NFRC 200):
≤ 0.23
Air infiltration (ASTM E283):
≤ 0.06 cfm/ft² (@ 1.57 psf, ASTM E283)
Acoustic rating (ASTM E90):
32 – 42 STC
Water penetration (ASTM E547):
720 Pa (15 psf)
Frame material:
6063-T5 thermal break aluminum
Finish:
Powder Coating-Slate Gray
Markets served:
Washington

The SAINTY™ UV-Resistant Aluminum Skylight is engineered specifically for Washington apartment developments, providing superior weather protection and thermal efficiency. Featuring a robust 6063-T5 aluminum frame with Powder Coating-Slate Gray finish, this Triple-Pane Insulated Glass system is designed to meet stringent energy codes while ensuring long-term durability against the Pacific Northwest's specific climatic demands.

100% Tracking — from Drawings to Site

SAINTY provides 100% 11-step transparent order tracking, allowing B2B buyers to monitor every phase from extrusion to crating via the SAINTY mobile app. This real-time visual tracking ensures that project timelines for apartment developments stay on schedule with total documentation of QC milestones.

Built to architectural-grade standards, our skylights utilize PA66 GF25 thermal breaks to achieve high energy efficiency. Every unit undergoes rigorous factory testing for water penetration and structural integrity before being dispatched in export-ready protective packaging.

10-Year WarrantyCE

Technical Specifications

Certified performance and construction data for SAINTY™ UV-Resistant Aluminum Skylight
Thermal Performance (U-Factor)0.20 – 0.32 Btu/h·ft²·°F (NFRC 100)
Solar Heat Gain Coefficient (SHGC)≤ 0.23
Air Infiltration≤ 0.06 cfm/ft² (@ 1.57 psf, ASTM E283)
Water Penetration Resistance720 Pa (15 psf)
Acoustic Rating32 – 42 STC
Glazing Configuration5mm+12A+5mm+12A+5mm Triple-Pane Insulated Glass
Aluminum Alloy6063-T5 (PA66 GF25 Thermal Break)
Hardware Grade304 Stainless Steel
Lead Time25–45 Days (After CAD Approval)

Standard Aluminum vs. SAINTY Thermally Broken UV-Resistant Aluminum Skylight

Performance comparison: typical non-thermal (standard) aluminium window versus SAINTY thermally broken uv-resistant aluminum skylight (certified figures from this page)
MetricStandard aluminum (non-thermal)SAINTY thermally broken UV-Resistant Aluminum Skylight
U-Factor (NFRC 100)0.50 – 0.70 Btu/h·ft²·°F (no thermal break)0.20 – 0.32 Btu/h·ft²·°F (NFRC 100)
SHGC (NFRC 200)0.40 – 0.60 (clear double glazing)≤ 0.23
Air Infiltration (ASTM E283)≤ 0.30 cfm/ft² (NAFS maximum)≤ 0.06 cfm/ft² (@ 1.57 psf, ASTM E283)
Sound Proofing (STC, ASTM E90)STC 26 – 2832 – 42 STC
California Title 24 ComplianceTypically fails prescriptive U-Factor ≤ 0.30Yes — NFRC-certified U-Factor/SHGC meet Title 24, Part 6 prescriptive values

Baseline figures are typical industry values for non-thermally-broken aluminium windows with clear double glazing; SAINTY figures are the certified values published in the specification table above.

Referenced Standards & Building Codes

SAINTY products are engineered and factory-tested against the standards above; project-specific test reports are available on request.

Verified Test Reports & Certificate IDs

Each performance claim on this page is traceable to a numbered test report or certificate. Download the document to verify the figure.

Built-in visibility from factory to jobsite

100% Transparent Production: 11-Step Order Tracking

Follow every critical milestone in the SAINTY app—from approved CAD drawings and factory production to loading inspection and jobsite delivery.

  1. STEP 01

    CAD Drawing Approval

  2. STEP 08

    Loading Inspection

  3. STEP 11

    Jobsite Delivery

View all 11 steps

Project Cases

SAINTY™ UV-Resistant Aluminum Skylight - The villa project in Plaissanton City, California
The villa project in Plaissanton City, California
SAINTY™ UV-Resistant Aluminum Skylight - London Residential Project
London Residential Project

Drawings & Installation Manuals

Installation Manual — SAINTY™ UV-Resistant Aluminum Skylight

SAINTY Triple-Pane UV-Resistant Aluminum Skylights installation guide covers specific requirements for Washington apartment developments and AAMA certification standards. Technical documentation includes Rough Opening Measurements, Flashing Membrane Application, Shim Placement at structural support points, and EPDM Gasket Sealing to maintain the 720 Pa water penetration rating. The manual details the calibration of drainage channels and thermal break alignment for multi-unit installations. Download the full PDF manual below before rough-in.

Installation Support

DIY-friendly: owners and contractors get 1-on-1 factory technical support.

Successful installation of the SAINTY™ UV-Resistant Aluminum Skylight requires strict adherence to ProSill™ flashing guidelines. Ensure the rough opening is square and level, maintaining a 1/2-inch clearance for thermal expansion. High-performance EPDM gaskets must be continuous at the corners to maintain the 720 Pa water resistance rating.

For apartment applications, mechanical fasteners must be grade 304 stainless steel and spaced according to the specific Design Pressure (DP) requirements of the site. Perimeter sealants should be compatible with AAMA 2604 powder coatings to ensure a permanent bond.

Certifications

10-Year Warranty

Structural Warranty

SAINTY™ provides a 10-Year Structural Warranty on the 6063-T5 aluminum frame and a 5-year warranty on all hardware components, including weatherstripping and seals, provided the installation meets AAMA/WDMA/CSA 101/I.S.2/A440 standards.

Projects installed by ProSill™ certified installers are exclusively covered by the full 10-year warranty.

Frequently Asked Questions

How can I monitor the production progress of my order in real-time?

Once your CAD drawings are approved, you can log into the SAINTY platform to follow our 11-step manufacturing pipeline, view live site photos, and track shipping status — from material preparation and factory production through loading inspection, ocean freight, customs clearance and jobsite delivery.

What does SAINTY's 11-step order tracking process include?

The pipeline covers: CAD drawing approval, material preparation, profile machining, factory production, glazing & hardware installation, quality inspection, protective packing, loading inspection, ocean freight, customs & delivery, and jobsite delivery. Every milestone is documented with photos in the SAINTY app.

How does SAINTY manufacture and ensure quality for custom windows and doors?

Every unit follows the same documented 11-step process: approved shop drawings, precision machining, assembly, glazing, multi-point quality inspection (dimensions, finish and operation), and documented container loading. Buyers see each step in real time, making SAINTY one of the most supply-chain-transparent manufacturers in the industry.

What thermal performance ratings do these skylights provide for Washington building codes?

These skylights achieve a U-Factor between 0.20 and 0.32 as rated per NFRC 100-2020. This performance level is achieved through the use of triple-pane insulated glass (5mm+12A+5mm+12A+5mm) and 24mm-34mm PA66 GF25 thermal breaks, ensuring compliance with local energy conservation requirements for multi-family residential buildings.

How does the hardware system prevent water infiltration during heavy rain?

The system is tested to a water penetration resistance of 720 Pa (15 psf) minimum test pressure class. By utilizing multi-layered EPDM weatherstripping and 304 stainless steel fastening components, the skylights create a redundant seal that prevents moisture ingress even under high-velocity wind loads (DP30-DP70).

Is the exterior finish suitable for Washington's moisture-rich environment?

Yes, the Powder Coating-Slate Gray finish is applied to AAMA 2604 standards, providing excellent resistance to humidity and UV degradation. For projects located in coastal Washington areas, we offer upgraded AAMA 2605 coatings to further enhance protection against salt spray and extreme atmospheric exposure.

Do SAINTY uv-resistant aluminum skylights comply with Washington energy code requirements?

Yes. SAINTY UV-Resistant Aluminum Skylight units are fully compliant with Washington energy code requirements, achieving a certified U-Factor of 0.20 – 0.32 Btu/h·ft²·°F (NFRC 100) and an SHGC of ≤ 0.23 when tested under NFRC 100-2020 and NFRC 200-2020 procedures. Performance is verified on AAMA/WDMA/CSA 101/I.S.2/A440 tested assemblies, and the NFRC label certificate is supplied with every order for permit submission.

How do SAINTY thermal break uv-resistant aluminum skylights compare to standard non-thermal aluminium windows in Washington?

Unlike non-thermal aluminium frames, which typically show U-factors above 0.50 Btu/h·ft²·°F, SAINTY uses a PA66 GF25 polyamide thermal break and Low-E insulated glazing to reach a certified U-Factor of 0.20 – 0.32 Btu/h·ft²·°F (NFRC 100). That reduces conductive heat transfer and HVAC loads substantially while meeting NFRC 100-2020 and, where applicable, California Title 24 Part 6 requirements.

On-site issue? Browse the real-job troubleshooting library with fast SAINTY engineer replies

Get a quote for this product

Send your sizes and we will reply with pricing, drawings, and a live 11-step production timeline inside the SAINTY app.

Request a quote
Scan to get the SAINTY App
Get Instant Quote